President University Repository

ANALYSIS OF BEARING CAPACITY AND SETTLEMENT OF BORE PILE FOUNDATION

Show simple item record

dc.contributor.author Yoneri, Oriza Sativa
dc.date.accessioned 2024-11-19T03:22:27Z
dc.date.available 2024-11-19T03:22:27Z
dc.date.issued 2023
dc.identifier.uri http://repository.president.ac.id/xmlui/handle/123456789/12148
dc.description.abstract This final project presents the bearing capacity and settlement that occurs on the bore pile foundation for a sulfuric acid tank with an operational weight of 796 kN, a diameter of 3 m, and a tank height of 6 m. The use of bore pile foundations is another alternative because there are existing buildings in the construction area. Bore pile foundation construction generally produces less vibration so it does not disturb existing buildings around the construction area. The foundation is crucial to the building's construction because it ensures the building's safety, stability, and structural integrity. Without a solid and powerful base, the structure can be severely damaged and even lead to a collapse. Calculate bearing capacity and settlement with a bore pile foundation depth of 5,15 m, using variations in 40 cm and 30 cm diameter variations. Based on SPT data using the Reese & Wright method, the allowable carrying capacity of a single pile foundation for a diameter of 40 cm is 293,6 kN, and for a diameter of 30 cm is 201,9 kN. The bearing capacity of the pile group is also calculated, with the results for a bore pile foundation with a diameter of 40 cm, namely 1001,54 kN with a total of 4 piles, while for a pile diameter of 30 cm, it is 990,91 kN with a total of 6 piles, these values are greater than the axial load (P) which is 931,63 kN. The results of calculating the settlement of a single bore pile using the Vesic method is 3,24 cm, and the group settlement is 7,41 cm, while with a pile diameter of 30 cm, the settlement of a single bore pile is 2,41 cm and settlement in the pile group is 7,23 cm. The settlement that occurs in both variations of pile diameter is said to be safe or still at the tolerable limit because they are smaller than the allowable settlement, which is around 15 cm. en_US
dc.language.iso en_US en_US
dc.publisher President University en_US
dc.relation.ispartofseries Civil Engineering;022202000026
dc.subject Bore Pile en_US
dc.subject SPT en_US
dc.subject Bearing capacity en_US
dc.subject Settlement en_US
dc.title ANALYSIS OF BEARING CAPACITY AND SETTLEMENT OF BORE PILE FOUNDATION en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account