QUALITY IMPROVEMENT OF G-31 DEFECT ON MASTER CYLINDER 2DP PRODUCT USING DEFINE, MEASURE, ANALYZE, IMPROVEMENT, AND CONTROL (DMAIC) METHOD IN GRAVITY DIE-CASTING DEPARTMENT

Show simple item record

dc.contributor.author Aziz, Muhammad Abdul
dc.date.accessioned 2026-01-20T01:43:27Z
dc.date.available 2026-01-20T01:43:27Z
dc.date.issued 2025
dc.identifier.uri http://repository.president.ac.id/xmlui/handle/123456789/13409
dc.description.abstract To maintain market share, the company guarantees high quality for the products offered to consumers. Master cylinder 2DP is one of the products produced at PT CHN and is one of the products with the highest production volume, but there are also many defects found for this product. In 2023, the total defect ratio of this product is 4.7 percents with the total number of defects is 53,430 pcs of 1,137872 products. To existing this problem, conduct the analyze using DMAIC Method. DMAIC method was chosen because it provides a systematic and data-driven approach to identify problems, analyze the root causes, and implement effective improvements. Pareto diagram is used to determine the highest defect ratio. G-31 defect is the most common type defect found in M/C 2DP production process with the number of defects is 30 percents. SPC calculation is used to assist this research in statistical calculation with P chart attributes. Fish-bone diagram is used to analysis the cause and effect for this problem. Lack skill of new operators (man) and lowering the thickness of core (machine) is main cause that caused this defect. To overcome these problems, improvements were made by standardizing the re- coating process on the core (mold). The trial stage (improvement phase) is already running in five days production. There was a defect reduction from previously 4.7 percent to 3 percent. There was an increase in the sigma value from 3 to 4 after the improvements phase was implemented. If the continuous monitoring is carried out in the long term, the reduction defect will be even more specific (significant) and get the better sigma value. en_US
dc.language.iso en en_US
dc.publisher President University en_US
dc.relation.ispartofseries Industrial Engineering;004202000064
dc.subject Quality Control en_US
dc.subject Defect Product en_US
dc.subject DMAIC Method en_US
dc.subject Master Cylinder Product en_US
dc.subject DPMO and Sigma Value en_US
dc.subject Pareto Diagram en_US
dc.subject Fishbone Diagram en_US
dc.title QUALITY IMPROVEMENT OF G-31 DEFECT ON MASTER CYLINDER 2DP PRODUCT USING DEFINE, MEASURE, ANALYZE, IMPROVEMENT, AND CONTROL (DMAIC) METHOD IN GRAVITY DIE-CASTING DEPARTMENT en_US